ITEM DETAILS
Meter Reading
2,948 Hours
Serial #
70 m Jib, Air Conditioner, Anti Two-Block, CXT-90II Load Moment Indicator


**No Title available. Bill of Sale will be provided upon request to convey ownership**

** Contact Joe Bruno at +1 (629)209-6655 or email Jbruno@ritchiebros.com or place offer above **

Please see seller supplied specification document attached in the documentation section below.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
CE Mark No CE mark found
Safety Certification Label There was no safety certification label located on the machine.
Safety Certification Report Safety Certification Report Not Available
Load Chart Yes Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
General Appearance #39 Click here to open photos and videos of this item.  
General Appearance #40 Click here to open photos and videos of this item.  
(37)


Safety
Description Rating Details  
Horn Operational
Safety Lock Out/Stop Not operationally checked Click here to open photos and videos of this item.  
Current Safety Manual No
Current Operator/Maintenance Manual No
(1)


Control Station
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Glass No visible damage Click here to open photos and videos of this item.  
Seats/Armrests Click here to open photos and videos of this item.  
Load Moment Indicator Not operationally checked with a load., CXT-90II Click here to open photos and videos of this item.  
Anti-Two-Block Not operationally checked with a load. Click here to open photos and videos of this item.  
Controls Click here to open photos and videos of this item.  
Remote Control Not operationally checked Click here to open photos and videos of this item.  
Load Charts Posted on cab wall, Chart book in cab Click here to open photos and videos of this item.  
Oil Pressure No oil pressure indicator
Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hoist Brakes Click here to open photos and videos of this item.  
Drum Rotation Indicator Operational Click here to open photos and videos of this item.  
Hour Meter/Odometer (Start) 2948.28 hrs Click here to open photos and videos of this item.  
Hour Meter 2948 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
Indication of Additional Hours Screen was swapped out, unsure of additional hours.
Air Conditioner Operational
Heater Operational Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
Control Station #26 Click here to open photos and videos of this item.  
Control Station #27 Click here to open photos and videos of this item.  
Control Station #28 Click here to open photos and videos of this item.  
(29)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Trolley Operational Click here to open photos and videos of this item.  
JIB Length 72.6 m overall length Click here to open photos and videos of this item.  
Slewing Motor Click here to open photos and videos of this item.  
Counterweights Click here to open photos and videos of this item.  
Limited Function Check The main chassis components functioned when checked without a load., Operator said everything functioned as it should
(23)


Specialty
Description Rating Details  
(18)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.