ITEM DETAILS
Meter Reading
452 Hours
Serial #
Enclosed Cab, Heater, 4x4 w/ 3 Way Steering, 3800 kg Max Weight Capacity, 9000 mm Max Lift Height, Bucket, Manual Coupler, 460/70R24 Tires, CE Plate, Ultra Low Sulfur Diesel, US EPA Certificate Label.

*** Copy of CE certificate.

*** Italian registration

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
CE Certificate Available Yes Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Exterior Lights Operational Click here to open photos and videos of this item.  
(28)


Safety
Description Rating Details  
Travel Alarm Operational
Horn Operational
Seat Belts Operational
Safety Lock Out/Stop Operational
Current Safety Manual No
Current Operator/Maintenance Manual No


Control Station
Description Rating Details  
Mirrors Left mirror missing Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Steering Control Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Oil Pressure The fault indicator shuts off after the engine oil pressure rises. Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hour Meter/Odometer (Start) 452 Hours Click here to open photos and videos of this item.  
Hour Meter/Odometer 452.4 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Heater Operational
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(18)


Engine
Description Rating Details  
Emission Certification Label Both EPA and EC certification Click here to open photos and videos of this item.  
Blow by @ idle (subjective observation) No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks
Fuel Leaks No dripping leaks
Cooling System Leaks No dripping leaks
Engine - Left Side Click here to open photos and videos of this item.  
DEF / AdBlue Tank Click here to open photos and videos of this item.  
Limited Function Check (Engine) The engine started and ran. Click here to open photos and videos of this item.  
(13)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Operational Click here to open photos and videos of this item.  
Drive Motors Click here to open photos and videos of this item.  
Front Drive Axle Click here to open photos and videos of this item.  
Rear Drive Axle Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
Drivetrain #1 Click here to open photos and videos of this item.  
(8)


Hydraulics
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Valves
Hydraulic Tank
Hoses (Hydraulics) Click here to open photos and videos of this item.  
Auxiliary Hydraulic Plumbing Not operationally checked; Front Click here to open photos and videos of this item.  
Boom Lift Cylinder(s) Click here to open photos and videos of this item.  
Telescopic Boom Cylinders
Limited Function Check The hydraulic system was operational.
Hydraulics #1 Click here to open photos and videos of this item.  
(14)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Boom Condition Click here to open photos and videos of this item.  
Left Side of Boom Click here to open photos and videos of this item.  
Right Side of Boom Click here to open photos and videos of this item.  
Steering Linkage Click here to open photos and videos of this item.  
Frame Condition
Limited Function Check The main chassis components functioned during a limited check.
Brake Control Click here to open photos and videos of this item.  
Brake Lines/Hoses
Park Brake
Limited Function Check - Brakes The brake system functioned, stopping and holding the machine.
Tire Brands Michelin XMCL
Left Front Tire Click here to open photos and videos of this item.  
Left Rear Tire Click here to open photos and videos of this item.  
Right Rear Tire Click here to open photos and videos of this item.  
Right Front Tire Click here to open photos and videos of this item.  
Wheel Condition
Wheel Studs, Nuts, Lugs
(17)


Specialty
Description Rating Details  
Loader Bucket Condition Click here to open photos and videos of this item.  
Loader Bucket Cutting Edge/Shanks/Teeth
Loader Quick Coupler Click here to open photos and videos of this item.  
(8)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.