Previous Next
Sold on
6/11/21
Winning Bid
US $101,000
Won using Buy Now Price
# of Bids
2
SOLD!
ITEM DETAILS
Meter Reading
1,533 Hours
Serial #
Enclosed Cab, Air Conditioner, Heater, Cummins 6 Cylinder Diesel Engine, Personnel Carrier Body

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
CE Mark CE Marked Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Glass No visible damage Click here to open photos and videos of this item.  
Exterior Lights Operational Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
(32)


Safety
Description Rating Details  
Travel Alarm Inoperable
Horn Operational
Seat Belts Operational
Safety Lock Out/Stop Operational Click here to open photos and videos of this item.  
Current Safety Manual No
Current Operator/Maintenance Manual No
(1)


Control Station
Description Rating Details  
Seats/Armrests Click here to open photos and videos of this item.  
Mirrors Click here to open photos and videos of this item.  
Steering Controls Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Dash Console Click here to open photos and videos of this item.  
Engine Oil Pressure The gauge registers in the operating range. Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 1,533.1 Hours Click here to open photos and videos of this item.  
Hour Meter 1,533.9 Hours, Operational hour meter - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Air Conditioner The ambient temperature is too cold to check
Heater Operational
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(24)


Engine
Description Rating Details  
Emission Label Click here to open photos and videos of this item.  
A/C Compressor In place; ambient temperature too cold to check operation Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks Click here to open photos and videos of this item.  
Fuel Leaks No dripping leaks Click here to open photos and videos of this item.  
Cooling System Leaks No dripping leaks Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(11)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Service Brakes
Drive Motors
Final Drives Click here to open photos and videos of this item.  
Limited Function Check (Drivetrain-Track) The drivetrain was operational without a load.
(2)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics)
Hydraulic Motors
Valves
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(2)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Frame Condition Click here to open photos and videos of this item.  
Limited Function Check The main chassis components functioned during a limited check.
Brake Type Hydrostatic
Park Brake
Limited Function Check - Brakes The brake system functioned, stopping and holding the machine.
(5)


Rubber Track Undercarriage
Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail.
Description Rating Details  
Roller Frames Click here to open photos and videos of this item.  
Grouser Height Measurement Left side: 34 mm, Right side: 34 mm
Track Belt Condition No visible damage Click here to open photos and videos of this item.  
Rubber Belt Drive Lugs No visible damage Click here to open photos and videos of this item.  
Track Tensioners No visible damage
Carrier Rollers Click here to open photos and videos of this item.  
Rear idler wear Click here to open photos and videos of this item.  
Track Rollers Click here to open photos and videos of this item.  
Sprockets Click here to open photos and videos of this item.  
(26)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Limited Function Check The main chassis components were operational in a limited check.
(14)
 

Oil Sample Analysis
  engine
date of analysis Mar 02, 2021
Silicon 10.25 PPM
Tin 0 PPM
Silver 0 PPM
Aluminum 1.01 PPM
Chromium 0.21 PPM
Lead 0 PPM
Copper 0.68 PPM
Nickel 0.05 PPM
Iron 4.9 PPM
Glycol NEG
Water NEG
Fuel <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.