ITEM DETAILS
C.E. NIEHOFF 1 cylinder diesel Engine, Container Enclosure, C.E.NIEHOFF & CO MEP-952B 5 kW Generator

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


Engine
Description Rating Details  
Engine #10 Click here to open photos and videos of this item.  
Fuel Type Diesel
Starter Operational
Fuel System Operational Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Air cooled
Oil Leaks No dripping leaks Click here to open photos and videos of this item.  
Fuel Leaks Fuel line Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Limited Function Check After jump starting, the engine ran. The engine would not re-start after shutting down without jump starting., The engine started and ran. The electric fuel pump and fuel shutoff were manipulated. The engine was run using an auxiliary fuel source., Fuel leaks at primary filter and flex hose at fuel pump. Click here to open photos and videos of this item.  
(11)


General Appearance
Description Rating Details  
DTID Click here to open photos and videos of this item.  
Serial Number / VIN Click here to open photos and videos of this item.  
Generator/Welder Serial Number B0034 Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
Cowling, Insulation and Belly Pans Click here to open photos and videos of this item.  
CE Mark No CE mark found Click here to open photos and videos of this item.  
(8)


Control Station
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Oil Pressure The fault indicator shuts off after the engine oil pressure rises. Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Run time short because of fuel leaks.
(3)


Electrical
The generator was not load checked during the inspection. IronPlanet does not guarantee the generators ability to run at its full rated kW output.
Description Rating Details  
Generator 5 KW rating Click here to open photos and videos of this item.  
Cables and Connections Click here to open photos and videos of this item.  
Emergency Shut Off Switch Not operationally checked Click here to open photos and videos of this item.  
Receptacles Not operationally checked Click here to open photos and videos of this item.  
Limited Function Check The main components appear to be in place. The generator is producing electricity.
(10)


Logistics
Description Rating Details  
Shipping Dimensions Length: 38”, Width: 35”, Height: 18”
Machine Weight Weight: 585 lbs
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.