2011 US EPA Label, Swing Boom, 44 in Stick, 9 in Rubber Tracks, Expandable Width Tracks

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.
 
Limited Function Check
Description Details
Engine Due to the condition of the unit, the engine could not be started.
Drivetrain The drivetrain could not be operationally checked.
Hydraulics The hydraulic system could not be operationally checked.
Deficiencies Deficient Components/Systems Include but are not limited to: The unit has been partially disassembled and parts/components are missing.


General Appearance
Description Rating Details  
Hour Meter / Odometer 0 Not Available, Meter reading could not be obtained - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed.
(5)


Control Station
Description Rating Details  
(4)


Engine
Description Rating Details  
Engine 2011 US EPA Label
(5)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
(4)


Hydraulics
Description Rating Details  
(4)


Chassis
Description Rating Details  
(3)


Undercarriage
Description Rating Details  
(2)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.