Previous Next
Auction Closed on
11/5/25
Asking Price
US $440,000
NOT SOLD
14 watchers
ITEM DETAILS
Meter Reading
4 Hours
Serial #
12 in Horizontal Auger Dredge, John Deere SE501687 Pump Engine, John Deere SE501687 Hydraulics Engine, Air Conditioned Operator Station

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
CE Mark No CE mark found
Hour Meter / Odometer 4 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Exterior Lights Operational Click here to open photos and videos of this item.  
(6)


Control Station
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Seats/Armrests Click here to open photos and videos of this item.  
Steering Controls Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Dash Console Click here to open photos and videos of this item.  
Engine Oil Pressure The gauge registers in the operating range. Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Air Conditioner Operational
Heater Inoperable, Seller has a new blower motor to repair in the box in the cab.
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(15)


Hull
Description Rating Details  
Floor Supports Could not be visibly checked
Fuel Tank Click here to open photos and videos of this item.  
Mooring Tie-Down Points Number of tie-down points 4 Click here to open photos and videos of this item.  
Transom Click here to open photos and videos of this item.  
Hull Bottom Click here to open photos and videos of this item.  
(8)


Engine
Description Rating Details  
Emission Label Click here to open photos and videos of this item.  
A/C Compressor Operational Click here to open photos and videos of this item.  
Blow-by (subjective visual observation) No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks
Fuel Leaks No dripping leaks
Cooling System Leaks No dripping leaks
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(12)


Water Pump
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Pump Housing Cast Click here to open photos and videos of this item.  
Self Prime System Not functionally checked Click here to open photos and videos of this item.  
Intake Check Valve No
Discharge Check Valve No
Limited Function Check (Water Pump) The pump was not operationally checked.
(2)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Hydraulic Motors Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses Click here to open photos and videos of this item.  
Cylinder(s) Click here to open photos and videos of this item.  
Cylinder Pins and Bushings Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(10)


Gantry
Description Rating Details  
Bridge Rails
Bridge Girders
Trolley
Hoists


Dredge
Description Rating Details  
Cutter Head
(15)
 

Oil Sample Analysis
  engine
date of analysis Aug 13, 2025
Silicon 4.82 PPM
Tin 6.92 PPM
Silver 0 PPM
Aluminum 1.98 PPM
Chromium 0 PPM
Lead 1.75 PPM
Copper 7.76 PPM
Nickel 0.29 PPM
Iron 5.55 PPM
Glycol NEG
Water NEG
Fuel <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.