Previous Next
Sold on
2/21/23
Winning Offer
US $51,000
# of Offers
14
# of Watchers
20
SOLD!
ITEM DETAILS
Meter Reading
1,089 Hours
Serial #
Enclosed Cab, Air Conditioner, Joystick Steering, Tier 4, 2016 US EPA Label, Requires Diesel Exhaust Fluid, 17.5 in Track Belts, Hydraulic Coupler, 74 in Bucket
LOCATED-IN-LUCERNE-OH

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Exterior Lights Operational Click here to open photos and videos of this item.  
(13)


Safety
Description Rating Details  
Travel Alarm Inoperable
Horn Operational
Seat Belts Operational
Safety Lock Out/Stop Operational Click here to open photos and videos of this item.  
Current Safety Manual No
Current Operator/Maintenance Manual Yes
(2)


Control Station
Description Rating Details  
Seats/Armrests Click here to open photos and videos of this item.  
Steering Controls Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Auxiliary Hydraulic Control Not operationally checked Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Dash Console Click here to open photos and videos of this item.  
Engine Oil Pressure The fault indicator shuts off after the engine oil pressure rises. Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 1089.8 hrs Click here to open photos and videos of this item.  
Hour Meter 1089 hrs, Operational hour meter - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Air Conditioner The ambient temperature is too cold to check
Heater Operational
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(17)


Engine
Description Rating Details  
Engine 2016 US EPA Label, Requires Diesel Exhaust Fluid
Emission Label Click here to open photos and videos of this item.  
A/C Compressor In place; ambient temperature too cold to check operation Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks Click here to open photos and videos of this item.  
Fuel Leaks No dripping leaks Click here to open photos and videos of this item.  
Cooling System Leaks No dripping leaks Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
DEF / AdBlue Tank Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(11)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drive Motors Click here to open photos and videos of this item.  
Final Drives Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(4)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Not visible
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses (Hydraulics) Click here to open photos and videos of this item.  
Auxiliary Hydraulic Plumbing Not operationally checked Click here to open photos and videos of this item.  
Loader Lift Cylinders Click here to open photos and videos of this item.  
Bucket Tilt Cylinders Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(6)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Frame Condition Click here to open photos and videos of this item.  
Belly Pans Click here to open photos and videos of this item.  
Lift Arm Condition Click here to open photos and videos of this item.  
Chassis to Arm Pins Click here to open photos and videos of this item.  
Quick Coupler to Arms Pins Click here to open photos and videos of this item.  
Limited Function Check The main chassis components were operational in a limited check.
(5)


Rubber Track Undercarriage
Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail.
Description Rating Details  
Roller Frames Click here to open photos and videos of this item.  
Grouser Height Measurement Left side: 13 mm, Right side: 13 mm
Track Belt Condition Click here to open photos and videos of this item.  
Rubber Belt Drive Lugs Click here to open photos and videos of this item.  
Front Idler Wear Click here to open photos and videos of this item.  
Rear idler wear Click here to open photos and videos of this item.  
Track Rollers Click here to open photos and videos of this item.  
Sprockets Click here to open photos and videos of this item.  
(14)


Specialty
Description Rating Details  
Quick Coupler Operational Click here to open photos and videos of this item.  
Loader Bucket Condition Hole worn in bottom Click here to open photos and videos of this item.  
Loader Bucket Cutting Edge/Shanks/Teeth Click here to open photos and videos of this item.  
(5)
 

Oil Sample Analysis
  engine
date of analysis Feb 11, 2023
Silicon 5.35 PPM
Tin 0 PPM
Silver 0 PPM
Aluminum 2.56 PPM
Chromium 0.19 PPM
Lead 0 PPM
Copper 2.93 PPM
Nickel 0.17 PPM
Iron 11.8 PPM
Glycol NEG
Water NEG
Fuel <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.