Previous Next
Ends
Subject to Offers
High Offer
CAD 40,000
 
  
Buy Now Price
CAD 59,000
You will confirm this action on the next page. How it works. How Make Offer works.
ITEM DETAILS
Meter Reading
2,991 Hours
Serial #
Enclosed Cab, Air Conditioner, Differential Lock, 12 Forward 12 Reverse, Power Shuttle, Left Hand Reverser, 111 hp Engine, 2011 US EPA Label, Front Weights, HID Lights, 2 Rear Remotes, 540/1000 PTO, 3-Point Hitch, 380/85R24 Front Tires, 18.4R34 Rear Tires, Bamford Turner EPPIII

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.
 
Model Description
Description Details


General Appearance
Description Rating Details  
CE Mark No CE mark found
Hour Meter / Odometer 2991 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Exterior Lights Operational Click here to open photos and videos of this item.  
(21)


Safety
Description Rating Details  
Horn Operational
Seat Belts Operational
Current Safety Manual No
Current Operator/Maintenance Manual Yes
(1)


Control Station
Description Rating Details  
Mirrors Click here to open photos and videos of this item.  
Seats/Armrests Click here to open photos and videos of this item.  
Hydraulic Controls Not operationally checked Click here to open photos and videos of this item.  
Steering Control Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Oil Pressure No oil pressure indicator
Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Air Conditioner Operational
Heater Operational
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(18)


Engine
Description Rating Details  
Engine 2011 US EPA Label
Emission Label Click here to open photos and videos of this item.  
A/C Compressor Operational Click here to open photos and videos of this item.  
Blow-by (subjective visual observation) Minor Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks Click here to open photos and videos of this item.  
Fuel Leaks No dripping leaks Click here to open photos and videos of this item.  
Cooling System Leaks No dripping leaks Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(17)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Click here to open photos and videos of this item.  
Clutch Engages
Front Drive Axle Click here to open photos and videos of this item.  
Rear Drive Axle Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(6)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Steering Linkage Click here to open photos and videos of this item.  
Steering Wheel Play
Frame Condition Click here to open photos and videos of this item.  
Limited Function Check The main chassis components were operational in a limited check.
Brake Type Hydrostatic
Park Brake Held against power
Limited Function Check - Brakes The brake system functioned, stopping and holding the machine.
Left Front Tire Click here to open photos and videos of this item.  
Left Rear Tire Click here to open photos and videos of this item.  
Right Rear Tire Click here to open photos and videos of this item.  
Right Front Tire Click here to open photos and videos of this item.  
Wheel Condition
Wheel Studs
(16)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Rear Remote Hydraulic Circuits Not operationally checked Click here to open photos and videos of this item.  
Mid Mount Remote Hydraulic Circuits Not operationally checked Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses Click here to open photos and videos of this item.  
Cylinder(s) Click here to open photos and videos of this item.  
Cylinder Pins and Bushings Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(13)


Specialty
Description Rating Details  
3-Point Linkage Click here to open photos and videos of this item.  
Counterweights No weight visible Click here to open photos and videos of this item.  
(8)
 

Oil Sample Analysis
  engine
date of analysis Oct 02, 2024
Silicon 0.95 PPM
Tin 2.08 PPM
Silver 0 PPM
Aluminum 0.66 PPM
Chromium 0 PPM
Lead 0.24 PPM
Copper 0.68 PPM
Nickel 0.68 PPM
Iron 2.63 PPM
Glycol NEG
Water NEG
Fuel <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.