ITEM DETAILS
Meter Reading
139 Hours
Serial #
60 kW, 240/416 Volts 3 Phase, 3000 GPH, 6 Cylinder Diesel Engine, Trailer Mounted, Integrated Fuel Tank, Air Brakes, 37,960 lbs. GVWR

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
Cowling, Insulation and Belly Pans Click here to open photos and videos of this item.  
(9)


Control Station
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Gauges Operational Click here to open photos and videos of this item.  
Oil Pressure 59 PSI Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 139 Hours Click here to open photos and videos of this item.  
Hour Meter 139 Hours - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational. Click here to open photos and videos of this item.  
Control Station #1 Click here to open photos and videos of this item.  
(8)


Engine
Description Rating Details  
Fuel Type Diesel
Blow by @ idle (subjective visual observation) No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Fuel System Operational Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks None seen
Fuel Leaks None seen
Cooling System Leaks None seen
Limited Function Check After jump starting, the engine ran. The engine would not re-start after shutting down without jump starting.
(7)


Electrical
The generator was not load checked during the inspection. IronPlanet does not guarantee the generators ability to run at its full rated kW output.
Description Rating Details  
Disconnect Switch Click here to open photos and videos of this item.  
Cables and Connections Click here to open photos and videos of this item.  
Emergency Shut Off Switch Operational Click here to open photos and videos of this item.  
Receptacles Click here to open photos and videos of this item.  
Limited Function Check Functioned when checked without a load.
(4)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Axle Condition Click here to open photos and videos of this item.  
Trailer Brakes Air Click here to open photos and videos of this item.  
Limited Function Check - Brakes The brakes were not operationally checked.
Tire Condition Click here to open photos and videos of this item.  
Tires 18/32" Tires Click here to open photos and videos of this item.  
Wheel Condition
Wheel Studs
Springs/Hangers Condition Click here to open photos and videos of this item.  
Tongue/ Hitch Condition No visible damage Click here to open photos and videos of this item.  
Lights/Wiring Condition Not operationally checked Click here to open photos and videos of this item.  
Marker Lights Functional The right rear marker is damaged. Click here to open photos and videos of this item.  
Brake Lights Functional Not operationally checked Click here to open photos and videos of this item.  
Frame Rails/ Main Beams Condition No visible damage Click here to open photos and videos of this item.  
Landing Gear / Tongue Jack Click here to open photos and videos of this item.  
Fuel Tank Condition Click here to open photos and videos of this item.  
(22)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.