ITEM DETAILS
1,673 Hours
60 kW, 120V Receptacles, 3,000 GPH, Diesel Engine, Fuel Tank, Portable, Tandem Axle Trailer Chassis

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Serial Number / VIN Click here to open photos and videos of this item.  
Generator/Welder Serial Number HX62729 Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
Cowling, Insulation and Belly Pans Click here to open photos and videos of this item.  
(18)


Control Station
Description Rating Details  
Gauges Click here to open photos and videos of this item.  
Oil Pressure
Warning Lights
Hour Meter 1673.7 Hours - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check The item was not operational. Ratings are based on a static inspection.
(3)


Engine
Description Rating Details  
Fuel Type Diesel
Starter Operational
Fuel System Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks None seen
Fuel Leaks Fuel line; Fuel tank Click here to open photos and videos of this item.  
Cooling System Leaks None seen
Limited Function Check The engine turns over but will not start.
(7)


Electrical
The generator was not load checked during the inspection. IronPlanet does not guarantee the generators ability to run at its full rated kW output.
Description Rating Details  
Generator Make and Model MEP-806B generator; Serial#: HX62729 Click here to open photos and videos of this item.  
Disconnect Switch
Cables and Connections
Emergency Shut Off Switch Click here to open photos and videos of this item.  
Receptacles Click here to open photos and videos of this item.  
Limited Function Check The unit could not be started and run. Several components could not be properly checked.
(5)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Axle Condition Click here to open photos and videos of this item.  
Trailer Brakes Air Click here to open photos and videos of this item.  
Limited Function Check - Brakes The brakes were not operationally checked. The brakes are caged.
Tire Condition Click here to open photos and videos of this item.  
Wheel Condition
Wheel Studs
Springs/Hangers Condition Click here to open photos and videos of this item.  
Tongue/ Hitch Condition No visible damage Click here to open photos and videos of this item.  
Lights/Wiring Condition Not operationally checked
Marker Lights Functional Not operationally checked Click here to open photos and videos of this item.  
Brake Lights Functional Not operationally checked Click here to open photos and videos of this item.  
Frame Rails/ Main Beams Condition No visible damage Click here to open photos and videos of this item.  
Landing Gear / Tongue Jack Click here to open photos and videos of this item.  
Fuel Tank Condition Click here to open photos and videos of this item.  
(15)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.