Previous Next
Sold on
10/19/16
Winning Bid
US $1,000
Won using Buy Now Price
# of Bids
SOLD!
ITEM DETAILS
Meter Reading
2,558 Hours
Serial #
6" Intake, 6" Discharge, Deutz Diesel Engine, Full Enclosure, Trailer Mounted, 8-14.5LT Tires, Surge Brakes, Pintle Ring

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
Cowling, Insulation and Belly Pans Click here to open photos and videos of this item.  
(4)


Control Station Ground
Description Rating Details  
Hour Meter (pre-inspection) 2,558 Hours Click here to open photos and videos of this item.  
Gauges Not operationally checked Click here to open photos and videos of this item.  
Function Controls Click here to open photos and videos of this item.  
Warning Lights Click here to open photos and videos of this item.  
Limited Function Check The item was not operational. Ratings are based on a static inspection.
(5)


Engine
Description Rating Details  
Emission Certification Label None found
Starter Not operationally checked
Exhaust System Click here to open photos and videos of this item.  
Oil Leaks None seen
Fuel Leaks None seen
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check (Engine) The engine could not be started.
(4)


Electric Operating System
Description Rating Details  
Operating Voltage 24 Volts
Battery Condition Weak or under-charged
Cables and Connections Click here to open photos and videos of this item.  
Limited Function Check The batteries were low on charge. The electrical system could not be operationally checked.
(1)


Water Pump
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Pump Housing Cast Click here to open photos and videos of this item.  
Self Prime System Hand primer Click here to open photos and videos of this item.  
Intake Check Valve No
Discharge Check Valve No
Limited Function Check (Water Pump) The pump was not operationally checked.;
(2)


Trailer Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Axle Condition Click here to open photos and videos of this item.  
Brake Lines/Hoses
Limited Function Check - Brakes The brakes were not operationally checked.
Tire Condition Some of the tires are flat/damaged. Click here to open photos and videos of this item.  
Wheel Condition Some of the wheels are dented/damaged.
Wheel Studs Damaged
Springs/Hangers Condition Click here to open photos and videos of this item.  
Tongue/ Hitch Condition Pintle ring Click here to open photos and videos of this item.  
Power Receptacle Functional Not operationally checked Click here to open photos and videos of this item.  
Lights/Wiring Condition
Marker Lights Functional Not operationally checked Click here to open photos and videos of this item.  
Brake Lights Functional Not operationally checked Click here to open photos and videos of this item.  
Frame Rails/ Main Beams Condition No visible damage Click here to open photos and videos of this item.  
Landing Gear / Tongue Jack Missing Click here to open photos and videos of this item.  
Tie Down Points/ Lashing Rings 4 Tie down points Click here to open photos and videos of this item.  
(12)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.