ITEM DETAILS
1 Hours
6" Intake, 6" Discharge, Self-Priming Pump, Perkins 4 Cylinder Diesel Engine, Trailer Mounted, 225/75R15 Tires, Surge Brakes, Pintle Ring, Bottom Mounted Fuel Tank, 600 GPM

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Paint
Sheet Metal (fiberglass) Condition
(4)


Control Station Ground
Description Rating Details  
Hour Meter (pre-inspection) 1 Hour Click here to open photos and videos of this item.  
Hour Meter 1 Hour - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Function Controls Click here to open photos and videos of this item.  
Oil Pressure 65 PSI Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational. Click here to open photos and videos of this item.  
(6)


Engine
Description Rating Details  
Emission Certification Label None found
Blow by @ idle (subjective observation) No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks None seen
Fuel Leaks None seen
Cooling System Leaks None seen Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check (Engine) After jump starting, the engine ran. The engine would not re-start after shutting down without jump starting. Click here to open photos and videos of this item.  
(9)


Water Pump
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Pump Housing Click here to open photos and videos of this item.  
Self Prime System Not operationally checked Click here to open photos and videos of this item.  
Intake Check Valve Click here to open photos and videos of this item.  
Discharge Check Valve Click here to open photos and videos of this item.  
Limited Function Check (Water Pump) The pump was not operationally checked.
(6)


Trailer Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Axle Condition Bent Click here to open photos and videos of this item.  
Limited Function Check - Brakes The brakes were not operationally checked.
Tire Condition
Tires Click here to open photos and videos of this item.  
Wheel Condition
Wheel Studs Click here to open photos and videos of this item.  
Springs/Hangers Condition
Tongue/ Hitch Condition Click here to open photos and videos of this item.  
Power Receptacle Functional Not operationally checked Click here to open photos and videos of this item.  
Lights/Wiring Condition Not operationally checked Click here to open photos and videos of this item.  
Brake Lights Functional Not operationally checked
Frame Rails/ Main Beams Condition Click here to open photos and videos of this item.  
Landing Gear / Tongue Jack Click here to open photos and videos of this item.  
Dampening Cylinder Not visible
Tie Down Points/ Lashing Rings Four Tie down points
(16)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.