Home Page / 2009 DRS Fermont MEP-804B 15kW Generator
 
Previous Next
Auction Date
Dec 14, time TBD
Starting Bid
US $2,100
Bid Increment
US $100

  
You will confirm this bid on the next page. How Bidding Works How Bidding Works
ITEM DETAILS
248 Hours
15kW, 120/208 Volts 3 Phase, 240/416 Volts 3 Phase, 120V Receptacles, Diesel Engine, Single Axle Trailer Chassis, Surge Brakes, 37x12.50R16.5LT Tires

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Serial Number / VIN 0001 Click here to open photos and videos of this item.  
Generator/Welder Serial Number FZ 62166 Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
Cowling, Insulation and Belly Pans Missing insulation Click here to open photos and videos of this item.  
(10)


Control Station
Description Rating Details  
Gauges Click here to open photos and videos of this item.  
Oil Pressure Click here to open photos and videos of this item.  
Warning Lights Click here to open photos and videos of this item.  
Hour Meter 248.9 - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check The item was not operational. Ratings are based on a static inspection.
(4)


Engine
Description Rating Details  
Fuel Type Diesel
Fuel System Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks None seen Click here to open photos and videos of this item.  
Fuel Leaks None seen Click here to open photos and videos of this item.  
Cooling System Leaks None seen Click here to open photos and videos of this item.  
Limited Function Check The engine could not be started.
(7)


Electrical
The generator was not load checked during the inspection. IronPlanet does not guarantee the generators ability to run at its full rated kW output.
Description Rating Details  
Generator Make and Model DRS Fermont; MEP-804B; Serial#: FZ 62166 Click here to open photos and videos of this item.  
Disconnect Switch Click here to open photos and videos of this item.  
Cables and Connections Click here to open photos and videos of this item.  
Emergency Shut Off Switch Click here to open photos and videos of this item.  
Receptacles Click here to open photos and videos of this item.  
Limited Function Check The unit could not be started and run. Several components could not be properly checked.
(5)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Axle Condition Click here to open photos and videos of this item.  
Trailer Brakes Not operationally checked Click here to open photos and videos of this item.  
Limited Function Check - Brakes The park brake is operational.
Tires 21/32" Click here to open photos and videos of this item.  
Wheel Condition
Wheel Studs
Tongue/ Hitch Condition Click here to open photos and videos of this item.  
Lights/Wiring Condition Functional Click here to open photos and videos of this item.  
Marker Lights Functional Yes Click here to open photos and videos of this item.  
Brake Lights Functional Yes Click here to open photos and videos of this item.  
Frame Rails/ Main Beams Condition Click here to open photos and videos of this item.  
Landing Gear / Tongue Jack Click here to open photos and videos of this item.  
Fuel Tank Condition Click here to open photos and videos of this item.  
(14)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.